Home   Kontakt   Impressum             

            

 

 

Protocols

 

1.  Immediately write in the first 3 minute data, then after 15 minutes before the first shutdown

   Second tension within the first 3 minutes, then the next 15 minutes

Protocol X00 = Raw protocols for semi-automatic metal relaxation

 

                            x0_MEMV_Metallent_Rapport_2016_r02cw   word

                            x0_MEMV_Metallent_Rapport_2016_r02cw   pdf

 

This is the fully automatic logging of the WIAP DK 20 software, which is included in the new MEMV 20 expansion device.

This software records more from the moment when no speed is manipulated

Protocol X01       PDF Printed protocol after input according to X00

                            x1 Hauesler_16_nr2_Vorlage_neu

 

Protocol X01       Excel is not released, only for Wiap customers

                            x1_Hauesler_16_nr1_Vorlage_neu  

 

Protocol X03       Jpg Printout DK20 From data communication devices 2015

                            x3_MEMV_Scan_Parotokoll_30_Min_Sample (2)

 

Protocol X03       Jpg Printout DK20 From data communication devices 2015

                            x3_Scan_Parotokoll_30_Min_Sample

 

Protocol X04       Jpg Printout DK20 From data communication devices 2015

                            x4_MEMV_Protokoll_30_Min_04

 

Protocol X05       Jpg Printout DK20 From data communication devices 2015

                            x5_MEMV_Protokoll_30_Min_01

 

Protocol X06       Jpg Printout DK20 From data communication devices 2015

                            x6_MEMV_Protokoll_30_Min_02

 

This is a detailed 24-point test report. It is used in all 3 axes in minimum 4 measuring points per axis. The difference determines between before and after.
The first measurement should take place within the first 3 minutes. The real value will be even more than the protocol shows in our case because the first voltage

reduction takes place during the first load plays on the component. Thus, we can not measure with the method. We are currently preparing a new test measurement

method, where 24 measurement points are determined immediately in the first few seconds. If a component has one or more death points, it can move through the

layer, the dead point can also be shifted, thus a MEMV vibration relaxation can be carried out

 

 

 

Protocol X10        excel    24 Measurement point log Acquisition of the entire component in all 3 axes Release only at Wiap customers

                             x10_MEMV_Diagramm_Haeusler_r19n_WS03 (2)

 

Protocol X10       pdf      24 Measurement point log Acquisition of the entire component in all 3 axes

                            x10_MEMV_Diagramm_Heusler_r19n_W

 

Protocol X11       excel   24 Measurement point log Acquisition of the entire component in all 3 axes Release only at Wiap customers

                            x11_MEMV_Diagramm_Haeusler_r19n_WS04 (2)

 

Protocol X11       pdf      24 Measurement point log Acquisition of the entire component in all 3 axes

                            x11_MEMV_Diagramm_Haeusler_r19n_WS04_Motorumspannuns (2)

 

Protocol X12       pdf      24 Measurement point log Acquisition of the entire component in all 3 axes

                            x12_MEMV_Diagramm_Promot_r19_WS04